Floor Penetrations
All MFMA manufacturers have detailed specifications that call for
installation of expansion voids at the perimeter and at all vertical
obstructions on most
types of their flooring systems. The installation of expansion voids at the
system perimeter and at all vertical obstructions is required in most floor
system specifications. As a general rule, MFMA recommends that no electric
fixtures, public address equipment outlets, sports equipment bases or bleacher
banks be anchored through maple sports flooring systems directly into the
concrete subfloor without first cutting surface maple and wood subfloor components
away from lag bases and all other permanent in-floor fixtures to provide
proper space for normal anticipated system movement. Installation of a 1-1/2" -
2" expansion void at the perimeter and at vertical obstructions is required
for most floor system configurations.
Systems such as the generic Channel
and Clip floors are designed to hold the flooring tightly in place, restraining
the system from
movement. Installation of a 1-1/2" - 2" expansion void
at the perimeter and at vertical obstructions is not usually
required with these system configurations.
If you have
additional questions, please contact MFMA's
Technical Director at 847-480-9138.